What you will see
The VCC Import action returns a failure and the desired setting fails to be set.
Specifically, bundles that have IMAGING UNIT alert settings will fail if applied to a device with EC4 (.P416) or newer firmware.
Devices with... | VCC keys (bundle.zip) origination... | Outcome... |
Pre-EC4 level FW... | Pre-EC4 bundle.zip with imaging unit alert settings | No problem updating to .P416 or greater. |
EC4 level FW... | Pre-EC4 bundle.zip with imaging unit alert settings | Imaging Unit alert failures when pre-EC4 bundle.zip file sent to EC4 device. |
Pre-EC4 level FW... | EC4 bundle.zip with imaging unit alert settings | Imaging Unit alert failures when EC4 bundle.zip file sent to a pre-EC4 device. |
There is no impact to the device in either case; however, a mismatched VCC key causes this failure. A key for color "cyan" may now be a key for "imaging unit alerts" or vice versa.
Affected products
This mostly affects monochrome printers and only impacts ~9 different possible bundles having a device configuration bundle that contains a supplies key for imaging units.
Suggested Remedies
Scenario (If...) | First ... | And then... |
A pre-EC4* device is already configured... | Upgrade FW. | ... |
A pre-EC4 device needs to be configured with a pre-EC4 bundle containing the supplies keys, and the device also needs to be upgraded to EC4... | Send the pre-EC4 bundle containing the supplies keys. | Update firmware to EC4. |
A pre-EC4 device needs to be configured with an EC4 bundle containing the supplies keys, and the device also needs to be upgraded to EC4... | Update firmware to EC4. | Send the EC4 bundle. |
You would like to convert a pre-EC4 bundle to an EC4 bundle (send the pre-EC4 bundle to a device with pre-EC4 firmware)... | Update device to EC4 or later firmware, but only after the pre-EC4 device has been configured with pre-EC4 bundle. | Export a new bundle. See Exporting or importing the Virtual Configuration Center (VCC) Bundle.ZIP configuration file |
*EC4 = .P416or greater (Last decimal place value for the 'Base' code level as seen under Device Settings.)
EC4 Fix Explanation
The NPA ID of supplies is not a fixed value between various product families and the VCC (though a static map exists for VCC-to-NPA IDs). This mismatch results in the above reported condition.
Two .P416 (EC4) firmware fixes that will ensure bundles remain consistent for future versions of firmware:
A fix to correctly map the Supplies names to look up the correct NPA.*SUPPLY.* for the machine. This ensures any bundles created after updating firmware to .P416 will be consistent.
A fix that allows only settings that can take effect to be accepted; for example, a color laser printer may have a single imaging unit and not one per color cartridge. This means that supplies.imaging is the correct key, not supplies.blackPC as originally expected.
# of IDs allocated for SUPPLY | Issue... | An example... |
12 | VCC <> NPA ID position for supply value variable for different products | Maintenance Kit "SUPPLY" - Color product
- Monochrome product
Position The absence of values for individual C,M,Y supply settings means a monochrome printer's position for Maintenance kit falls into a different position. |
Get In Touch With Lexmark! for contact information.