Skip to Content Information Center
Lexmark XM1145

Lexmark XM1145

31.25 CTLS Calibration Capacitor Reading Is Too Low

Defect Symptom

Error 31.25 – Capacitive Toner Level Sensing (CTLS) Calibration capacitor reading is too low. Possible issue exists with the CTLS circuit.

Customer Repair Action & Troubleshooting

  1. Remove and re-install the Imaging Unit; ensure that it is seated properly.

Repair Sequence 1 (Copy into Siebel)

  1. Try swapping Imaging Units if possible.

Parts repair 1

N/A

Repair sequence 2 (Copy into Siebel)

  1. Replace Controller Board.

Parts repair 2

40X8025 – Controller Board MS310d - DO NOT recommend for first repair call 40X9656 – Controller Board MS312dn 40X9657 – Controller Board MS315dn, MS415dn 40X8026 – Controller Board MS310dn 40X8027 – Controller Board MS410d - DO NOT recommend for first repair call 40X8028 – Controller Board MS410dn 40X8029 – Controller Board MS510dn 40X8030 – Controller Board MS610dn 40X8388 – Controller Board MS610de 40X9251 – Controller Board MX310 40X9252 – Controller Board MX410 40X9253 – Controller Board MX51x 40X9254 – Controller Board MX61x

LEGACY ID: SO7333

Was this article helpful?