Miscellaneous Security Settings menu

Note:  This menu appears only in touch‑screen printer models.

UseTo

    Login Restrictions

  • Login failures
  • Failure time frame
  • Lockout time
  • Panel Login Timeout
  • Remote Login Timeout

Limit the number and time frames of failed login attempts from the printer control panel before all users are locked out.

Notes:

  • “Login failures” specifies the number of failed login attempts before users are locked out. Settings range from 1 to 10. 3 attempts is the factory default setting.
  • “Failure time frame” specifies the time frame during which failed login attempts can be made before users are locked out. Settings range from 1 to 60 minutes. 5 minutes is the factory default setting.
  • “Lockout time” specifies how long users are locked out after exceeding the login failures limit. Settings range from 1 to 60 minutes. 5 minutes is the factory default setting.
  • Panel Login Timeout specifies how long the printer remains idle on the printer control panel before automatically logging the user off. Settings range from 1 to 900 seconds. 30 seconds is the factory default setting.
  • Remote Login Timeout specifies how long a remote interface remains idle before automatically logging the user off. Settings range from 1 to 120 seconds. 10 minutes is the factory default setting.

    Minimum PIN Length

  • 1–16

Limit the digit length of the PIN.

Note:  4 is the factory default setting.