Step 1 Make sure all the packing materials on the imaging unit are removed. Does the problem remain? | Go to step 2. | The problem is solved. |
Step 2 Reseat the cyan, magenta, and yellow developer units in the imaging kit. Reseat the imaging kit. Enter the Diagnostics menu, and then navigate to: Advanced Print Quality Samples > Advanced Print Quality Samples Check the test page.
Does the problem remain? | Go to step 3. | The problem is solved. |
Step 3 Check the developer hold down arms and springs for damage, and replace if necessary. See Developer hold down removal. Does the problem remain? | Go to step 4. | The problem is solved. |
Step 4 - If the affected color is cyan, magenta, or yellow, then replace the developer unit of the affected color.
- If the affected color is black, then replace the imaging unit.
Does the problem remain? | Go to step 5. | The problem is solved. |
Step 5 Replace the imaging kit. Does the problem remain? | Contact the next level of support. | The problem is solved. |