121.00 | Fuser failed to reach the temperature during warm‑up. | See Fuser temperature error service check. |
121.01 | There was an attempt to heat fuser, but it was not installed. |
121.02 | Fuser went over the required temperature during EWC/line voltage detection. |
121.03 | Fuser hardware and driver mismatch. |
121.04 | There was an attempt to heat fuser, but fuser relay was open and fuser PIC microcontroller did not report an error or did not respond. |
121.05 | There was an attempt to heat fuser, but fuser relay was open and fuser PIC microcontroller reported an error. |
121.06 | Fuser power is at 100% but did not reach the required temperature. |
121.08 | Fuser did not reach the required temperature while the page is in the fuser. |
121.09 | Fuser did not reach the required temperature for motors. Note: Not applicable to standby mode. |
121.10 | Fuser did not reach the required temperature during start of EWC/line voltage detection. |
121.11 | Fuser reached the required temperature during final EWC/line voltage detection too late. |
121.12 | Fuser did not reach the required temperature during final EWC/line voltage detection. |
121.13 | Fuser reached the required temperature during final EWC/line voltage detection too fast. |
121.19 | Fuser high power trace reached the required temperature during final EWC/line voltage detection too fast. |